FPIB1 series miniature moulded case circuit breakerFPIB1 Series product serves in the circuit of AC 50/60 HZ with rated voltage up to 400V , and rated current up to 32A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value.It can effectively protect personal..
 
DPN/DZ30 Miniature Circuit Breaker /IEC60898 mini circuit breaker/IEC60898 circuit breaker/IEC60898 MCB 1.Pole:1P+N2.AC 230V3.C Curve4.IEC60898 standard5.Short-circuit capacity:4.5KA6.Current: 3,6,10,16,20,25,32A7.Frequency:50/60HZ8.Installation: Din rail 35mm Application: The product is applicable to protect line conductor and overload, and..
 
-------------------------------------------------------------------F360 earth leakage circuit breaker ELCB,RCCB ------------------------------------------------------------------- APPLICATIONThe Residual Current Device (RCD) NFIN is in conformity with the standards of IEC 1008, VDE 0664, CEE27 and BS 4293.It can cut off the fault circuit..
 
MCCB/CM3/ Moulded case circuit breaker ApplicationCM2 Moulded case circuit breaker is suitable for wires with AC 50Hz (or 60Hz), rated working voltage of 660V(690V) and below, DC 250V and below, rated current of 12.5A-800A, to distribute electrical energy, and to work as un-frequent switch-on and switch-off under normal conditions, and carry..
 
VS1-12/24 model indoor AC HV vacuum circuit breaker can be used in indoor with three phases, 50Hz, rated voltage 12/24KV system. It mainly serves in mineral enterprise, power plant and substation for control and protection of electric equipment. It can be installed both in trolley type switchgear and fixed type switchgear. Table 1 Basic..
 
ST-1020A Miniature Circuit BreakerSpecification:1) Rating current: min. 5A, max. 50A2) Working voltage: min. 5VDC, max. 50VDC3) Application scope: it is widely used in the automotive industry Electrical goods, winch machine, DC power equipment, electric vehicles, chargers, motor , And other electrical products overcurrent protection of..
 
Type LW36-126(252) Outdoor Self-energized High-voltage SF6 Circuit Breaker Product OverviewType LW36-126(252) outdoor self-energized high-voltage SF6 circuit breaker is applicable in the alternating current 50Hz, 110-220kV power system, it can be used as the electrical protective and control device in the power system, it also can be deemed as..
 
SEMKO approval C45N Mini Circuit BreakerC45N Mini Circuit Breaker Product Description 1,Voltage:220~380V2,Current:2~63A3,Break capacity:6KA4,Certifucate:CB/SEMKO5,Standard:IEC60898DZ47 seriescircuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system.The product..
 
ZN63-12E(VS1) series of vacuum circuit breaker is three-phase A.C. 50Hz indoor high-voltage distribution device with 12KV rated voltage and below which can match with GZS1 type cubical switchgear. It is suitable to control and protect transmission and distribution system such as power generation plant and substation, especially used in the..
 
Indoor vacuum circuit breakertype VZG-12 sealed terminal indoor high votage vacuum circuit breaker Product OverviewThis circuit breaker is a kind of indoor high-voltage switchgear under three-phase AC 50Hz, 12KV rated voltage. It can be used as the electrical protective and control device in the power supply and distribution system and..
 
[D&C] shanghai delixi DZ47 100HD 100A MINI Circuit breakerProduct DescriptionAPPLICATION DZ47-100 series circuit breaker is with high breaking capacity, and with double protection of overload and short circuit. It is mainly used in the circuit of AC 50160Hz, rated voltage of single pole 230V, two, three or four pole up to 400V, and rated..
 
Miniature Circuit BreakerStandardGB10963 Circuit Breakers for Over Current Protection for Household and Similar InstallationIEC60898 Circuit Breakers for Over Current Protection for Household and Similar InstallationOperation Condition1. Ambient temperature: -5~+40'C2. Altitude <2000m3. Pollution grade: 24. Installation sort: IIISpecial..
 
medium voltage outdoor vacuum circuit breaker (vcb) Main Technical Data Rated voltage kv12Rated frequenceHz50Rated lighting impulse withstand voltagekv75Rated short-time power frequency withstand voltage(dry) kv42Rated short-time power frequency withstand voltage(humid) ..
 
Product DescriptionElectrical Equipment & Supplies&Circuit Breakers, mini circuit breaker General information of circuit breaker :TS series circuit breaker can be widely used in various motors juice extractor and massagers. The single pole contact opens when temperature range is reached. it has two terminals, one is plastic and the..
 
SpecificationsMCB 1.Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, 4P 2.Rated Current (A):1, 2, 3, 4, 6, 10, 16, 20,25, 32, 40, 50,63 ,100 Number of Poles1P, 1P+N, 2P, 3P, 3P+N, 4P Rated Current (A)1, 2, 3, 4, 6, 10, 16, 20,25, 32, 4050, 63100Breaking Capacity (A)600045004-10KARated Voltage (V)230/400Rated..
 
Specifications Application range DZ47-100 mini circuit breaker is applied in the circuit of AC50Hz/60Hz, rated current 100, rated voltage 230V/400V or below. This product is mainly used in the electric circuit and equipment of modern buildings, to protect them from the overload, short circuit and unfrequent operating and isolution.Merits high..
 
1,Application and range of application The NF-CP MCCB CIRCUIT BREAKER series plastic outer covering type circuit breaker (hereafter refers to as circuit breaker), is this company uses the international advanced design, one of the technique of manufacture development, development new circuit breakers. Its fixed isolation voltage is 690V, is..
 
1.ApplicationDZ47B-100S high breaking capacity Mini Circuit Breaker is mainly apply to AC 50 HZ or 60 HZ ,Rated voltage 230V/400V,Rated current :63,80,100A .Poles:1P+N,2P 3P+N,4P.The DZ47B-100S is used for remote controlling the circuit breaking and automatic symbol control breaking .At the same time providing overload and short-circuit..
 
Function and Feature:Protection against earth/leakage current and residual current,fuction of isolationProtection against fire hazard caused by insullation faultsResidual fault current indication6kA high breaking capacityPin/fork type busbar terminal connectionFire resistant plastic parts withstand abnormal heating and strong..