Chongqing Joywell Nasal CE Approved CPAP Auction for OSA Sleep Apnea

Location:
Chongqing, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C
Categories:

Product Description

Chongqing Joywell Nasal CE Approved CPAP Auction for OSA Sleep Apnea

1.Overview

A continuous positive airway pressure (CPAP) machine is used mainly by patient for the treatment of sleep apnea at home. Obstructive sleep apnea occurs when the upper airway becomes narrow as the muscles relax naturally during sleep. This reduces oxygen in the blood and causes arousal from sleep. The CPAP machine stops this phenomenon by delivering a stream of compressed air via a hose to a nasal pillow, nose mask or full-face mask, splinting the airway(keeping it open under air pressure)so that unobstructed breathing becomes possible, reducing and/ or eliminating apneas and hypopneas. This has an additional benefit of reducing or elimination the extremely loud snoring that sometimes accompanies sleep apnea.

CPAP treatment can be highly effective in treatment of obstructive sleep apnea. For some patients, the improvement in the quality of sleep and quality of life due to CPAP treatment will be noticed after a single night’s use. Often, the patient’s sleep partner also benefits from markedly improved sleep quality, due to the amelioration of the patient’s loud snoring. It is the best way to help patients continue therapy by educating them on the health risks of sleep apnea and providing motivation and support.

a) Safety Introduction:(Please accept the belowed requirements to avoid to happen a accident)

1.The instrument is for indoor work,it should work in normal room temperature.

2To use the instrument by the doctor's advice, or only under the guidance of professionals.

3.To adjust the treatment pressure by the hospital’s doctors or licensed personnel.

4.The instrument used only for positive airway pressure, non-life support for critically ill patients.

5.Before using,to check your power strip,in condition of no damage,no leakage,then plug in, to ensure the safe use of electricity.

6When to transfer or to handle equipment, first turn off the power switch,then unplug the power plug.

7.To ensure fresh air indoors, not use in a hazardous gas environments.

8.If added the oxygen,to handle at the oxygen mask department.To prohibit to work in the intake of the instrument! To avoid burning.

9.After putting water into the humidifier, please do not flip the apparatus,to avoid water into the instrument to burn circuit. If do not use it for long-term,drain water from wet tank to prevent mildew.

10.Do not disassemble equipment chassis. .

b)Reliability Introduction

While the instrument works,if a power downs or a power lines is off, the instrument will alarm by beep, then, should turn off the power switch on back baord and check the cause,in case the power cord off,please re-plugged the power cord and then boot in order.

c) Travel with portable machine

The instrument is equipped with a special backpack for convenient travel, with 110v/230v manual conversion, can be adapted throughout the grid.

(d) Application Scope

This instrument applies to hospitals and family therapy obstructive sleep apnea syndrome.

e) Features

1.Enhanced digital temperature control, stable humidification effect,low body temperature .

2.Constant temperature and humidification in one, smaller volume, easy to carry.

3.Delaying step-up, comfortable sleep in condition of low pressure,.

4.With the power off alarm to ensure safety.

5.Low noise.

2.Main Specifications

1, Normal Working Conditions

Environmental temperature: 5 °C ~ 40 °C;

Relative Humidity: ≤ 80%;

Atmospheric pressure: 700hPa ~ 1060hPa;

1. Power Supply: AC voltage 110V ~ 230V ± 10%; Frequency 50Hz (or 60Hz).

2, The capacity of constant temperature wetting tank: 250mL.

3, Weight: 1.8kg.

4, Input power: 180VA.

5, The working system: continuously.

6, Security types: II class, type BF.

7, Fuse: 220V, 5A; Φ5mm × 20mm.

8, Pressure adjustment range: 4.0hPa ~ 20.0hPa ,adjustable interval 0.5hPa.

9, With 0 ~ 45min delaying step-up function, seting the interval 5min.

10,Humidication temperature is adjusted by 16 stalls,the temperature of the air outlet is less than 41 °C.

11, The machine noise: ≤ 45db.

12, Continuous working time: 8h-12h.

Normal Question and Treatment

Problems and Failure

Phenomena

Solution

Mouth drying,thoat dry-

ing

Mouth drying,thoat drying after getting up

Add heating temperature, adjustment pressure

Nasal mucosa drying

Nasal disease and cold

before bedtime drop nasal by ephedrine

to enhance wetting

Interruption treatment night

Remove mask automatically noct-

urnal

Pressure adjustment is unsuitable,comp-

ression or decompression

Fullness in head,dizz-

iness

Fullness in head,dizziness after getting up

Pressure adjustment is unsuitable,com-

pression or decompression

Blood pressure is low

After waering CPAP machine for period

Reducing the use of antihypertensive drugs or see doctor

Chest pain, coughing

After waering CPAP machine for period

Reducing the use of antihypertensive drugs or see doctor

There is water inside mask

There is water inside mask or tube.

Reducing the wetting, increase the indoor temperature

Low pressure

After using in period,feeling low pressure

Wash filtration cotton to reduce indoor dust and pipeline leak

High outlet temperature

After using in period,feeling higher temperature

Wash filtration cotton to reduce indoor dust

Don’t alarm

No sound after taking off the mask alarm

Check alarm setting,to return to factory for repairing

No normal outlet air

Right showing,no wind

To return to factory for repairing

Starting key failure

Turning on,can’t start

To return to factory for repairing

MORE DETAILS

ACCESSARIES

CERTIFICATES

FACTORIE'S VIEW



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Chongqing Joywell Trade Co., Ltd.
Phone Number:
  86-23-67726679,67742083
Fax Number: