AC High Voltage SF6 Vacuum Circuit Breaker

Location:
Xiamen, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

AC High Voltage SF6 Vacuum Circuit Breaker

Description & Application

Outdoor ac hv vacuum circuit breaker is composed of outdoor pole-mounted vacuum circuit breaker, fault detector and outer voltage transformer, which are electrically connected with each other by aviation socket and outdoor sealing cable. With functions of fault detecting, protecting & controlling and communication, it can examine the mA-level of zero-sequence current and the fault current of phase to phase short-circuit, then automatically cut off the single phase earthing fault and phase short-circuit fault.

Technical Parameter & Detail Show

Technical Parameter

ItemUnitData
Rated CurrentA630
Rated VoltagekV11
Rated Insulation Level1 min Power Frequency Withstand VoltageDry (Phase to Phase, Phase to Earth/Across the Isolating Distance)42/49
Wet (Phase to Earth, External Insulation)34
Lightning Impulse Withstand Voltage (Peak) (Phase to Phase, Phase to Earth/ Across the Isolating Distance75/85
Rated FrequencyHz50
Rated Short-Circuit Breaking CurrentkA20, 25
Rated Short-Circuit Making Current (Peak)50, 63
Rated Peak Withstand Current50, 63
Rated Short-Time Withstand Current20, 25
Rated Short-Time Withstand Times4
Rated Operation Sequence Open-0.3s-Close & Open-180s-Close & Open
Break Times of Rated Short-circuit Breaking Currenttimes30
Mechanical Life10000
Rated Operating Voltage (Rated Auxiliary Circuit Voltage)V220

Note:

Once the product is used in the place higher than 1000m, the insulation withstand voltage should be correspondingly amended according to standard GB/T 11022-1999.

Material

Current Transformer Assembly

Each phase (Phase A, Phase C) in circuit breaker is installed 1pc current transformer for phase protection, the transformation ratio is 50~600/1.

Zero-sequence Current Transformer

1PC zero-sequence current transformer is installed in circuit breaker, the transformation ratio is 20/1. It should keep linear relationship during 0.2~6A, the transformation ratio deviation should be lower than 3% on condition of rated load. When the zero-sequence current is 400A the second time output current should be no less than 6A.

Operation Power Supply

1) Circuit breaker needs operating power when working. The operating power can be through AC 220V or DC 20V power (Voltage should be the same with power supply of controller),but it usually gets AC 220V power by installing a voltage transformer in 10kV line.

2) The external operating voltage transformer can be selected by user, for convenient installation the outdoor item with fuse is priority choice. If choose non-fuse item, an outdoor fuse shall be installed additionally for power transformer protection.

Watchdog

If install a power accept circuit breaker (usually called” watchdog”) at the responsible point of branch line or terminal user, it will judge the fault (over current, short-circuit, single phase earthing, etc.), automatically disconnect it, and keep normal electric power for non-fault users, suitable for incoming T connection or terminal connection as well as other satisfactory branch connecting positions.

Application Conditions

1 Ambient Temperature: -40°C~+40°C, Daily range of temperature: ≤25°C

2 Max Wind Speed: ≤ 35m/s

3 Application Site: No danger of inflammable, explosion hazard, strong chemical corrosion (such as acid, alkali or fume etc.) and violent vibration

4 Elevation:≤1000m (If beyond 1000m, should reconfirm with manufacturer)

5 Thickness of Covering Ice: ≤10mm

6 Class of Air Pollution: Level 4

7 Seismic Intensity: ≤8

7 Neutral Point Earthing Method: ungrounded, grounded through arc extinction coil, grounded by small resistance.

Appearance & Installation Dimensions

Base Installation Dimension

Standards

For Switch Series

DL/T403

GB1984

GB311.1

GB3309

GB4208

GB/T11022

DL/T593

DL/T884

DL/T615

GB8905

GB50150

For Controlling Terminals:

GB/T726-2000

GB/T726-2000

Service

Shipping

1 Sea Way

2 Air Way

3 Express

Payment

1 PayPal

2 West Union

3 Wire Transfer

4 T/T

We’re always at your service, any question feel free to contact us.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 DNK (Xiamen) Electrical Co., Ltd.
Phone Number:
  0086-592-2068080
Fax Number:
 0086-592-2038080