10KV 30KVA Dry type Transformer

Location:
Shanghai, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

•Application Of Products

Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin. Thanks to advanced technology, quality raw materials , scientific management, and perfect inspection means ,our products have the following features:

The coil is reinforced with glass fiber and cast under vacuum with filler epoxy resin. It has good mechanical properties, is free of crack and inner bubble and has low local discharge, high reliability, and long service life.

The high-and low-voltage systems are cast under vacuum, thus the coil will not absorb moisture; the clamps of core are subjected to corrosion-resistant treatment and it may run under high temperature or other serious environments.

Flame retardancy , explosion-proof and no environmental contamination. The insulating materials in the coil such as glass fiber are self-extinguishing and they will not cause fire by the arc resulted from short-circuit . The resin will not generate toxic or harmful gas under high temperature.

Gas duct is embedded inside it to enhance the radiation power and over-load capacity.

Low loss and low noise. The core is lapped with 45 full-miter and the step-type lamination effectively improves distribution of magnetic flux at core corners, and greatly reduces the no-load loss and the nose level.

It highly withstands short-circuit and lightning impact.

Small in volume, light in weight, safe in running and free of maintenance.

As per users’ requirements the transformer may be provided with casing and blower fan.

•Main Technical Parameters for 10kV SC(B) -30-2500 type


Rated power
(kVA)

High Voltage
(kV)

H.V Tap range

Low Voltage
(kV)

Connection Symbol

Short-Circuit Impedance
(%)

No-load Loss
(W)

On-Load Loss
(W)

No-load Current
(%)
Insulation ClassNoise
(dB)
Weight
(kg)
Overall dimension(mm)Gauge
(mm)
SC(B)
9
SC(B)
10
SC(B)
9
SC(B)
10
LWH
306
6.3
10
10.5
11
±5%
OR
±2×2.5%
0.4Yyn0
Dyn11
42201907507102.3F40330990660760550×550
50310270106010002.2403601000660790550×550
80420370146013801.7404701050660820550×550
100450400167015701.7405201080660860550×550
125530470196018501.5416201120760900660×660
160610540225021301.5427901200760950660×660
200700620268025301.34288012408201100660×720
250810720292027601.344100011008201160660×720
315990880367034701.146112011108201240660×720
4001100980422039901.146136011308201360660×720
50013101160517048801.147146011408201430660×720
63015101340622058800.947153012808201350660×720
630614601300631059600.947157012808201300660×720
80017101520736069600.948185012908201430660×720
100019901770861081300.948232014209601480820×910
1250235020901026096900.949269014309601620820×910
16002760245012400117300.9503130146096017501070×910
20003400305015300144500.75236001900###19401070×1205
25004000360018180171700.75545602030###20201070×1205

Note: All listed parameters just for your reference, the final data will be based on the drawing of

our products,meanwhile they can be adjusted as per customers' requirement.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Shenda Electric Group Co., Ltd.
Phone Number:
  0086-21-52209979 - 808
Fax Number:
 0086-21-52182883