S-400-13.8 switch mode power supply smps

Location:
Y, U E
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

S-400-13.8 Switch Mode Power Supply Smps

Specification:

Model

Performance

S-400-9

S-400-12

S-400-13.5

S-400-24

S-400-48

DC output voltage

9V

12V

13.5V

24V

48V

Output voltage tolerance(Note 2)

±1%

±1%

±1%

±1%

±1%

Rated output current

43A

33A

29A

17A

8.3A

Output current range

0-43A

0-33A

0-29A

0-17A

0-8.3A

Ripple and noise(Note 3)

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

Inlet stability(Note 4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note 5)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

378w

396W

400W

400W

400W

Efficiency

78%

83%

85%

85%

86%

DC voltage adjustable range

±10%

±10%

±10%

±10%

±10%

Input voltage range

170~264VAC

Input current

5.6A/115V 2.8A/230V

Surge Current

40A/230V

Leakage Current

<3.5mA/240VAC

Overload protection

105%-150%type:pulsing hiccup shutdown Reset:Automatic recovery

over-voltage protection

9.4-10.9V

13.8-16.2V

15.5-18 .2V

18-21V

27.6-32.4V

33.7-39.2V

57.6-67.2

V

High temperature protection

ERH3>=65°C-70°C FAN ON. <55-60°C FAN OFF.>=80-85°C cut off output(5-15V)-(24-48)

temperature coefficient

±0.03%°C(0~50°C)

Start-up,rise,hold up time

1.5s,50ms,20ms

shock resistance

10~500Hz,2G 10min./1circle,Period for 60min.,Each axes

Withstand voltage

Input and Output internal:3KvAC,input and enclosure:1.5KvAC,output and enclosure:

0.5KvAC

Insulation Resistance

Input and Output internal: input and enclosure,output and enclosure:500VDC/100M Ohms

work Temperature/humidity

-10°C~+60°C,20%~90%RH

storage temperature /humidity

-20°C~+85°C,10%~95%RH

Outline dimension

215*115*50mm CASE:912

Weight

2.3Kgs

Safety standards

Meet UL 1950 requirement ( Not apply for the mark )

EMC Standards

CISPR22(EN55022),IEC1000-4,2,3,4,5,6,8,11IEC1000-3-2

Note:

1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH Humidity.

2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).

3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.

4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.

5.Load stability test: the load from 0% to 100%.

6.C3,4,41 must remove.

Drawing:

Physical Photos Display:



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Yueqing Onlybo Instruments Co., Ltd.
Phone Number:
  0086-577-27878258
Fax Number:
 0086-577-27878258