Home use 1000VA 650 Va ups power

Location:
shenzhenChina (, Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

Home use 1000VA 650 Va ups power

1. Main features:

Automatic buck and boost AVR function, wide input voltage 145-280VAC.
BYPASS outlet available, user can connect equipment of heavy load without damaging UPS.
Advanced automatic constant charging circuit, prolongs battery life.
Battery low voltage, overload & short circuit protection.
Lead-Acid, maintenance free battery inside, provides strong power to users.
Boost and buck AVR (Auto voltage regulation).
Fully digitized microprocessor controlled.
Energy saving function (UPS green mode).
50/60Hz frequency auto sensing and selection.
Cold start function (DC power on).
Lightning and surge protection.
Short circuit and overload protection.
Advanced battery management (ABM technology).
Tel/Modem internet surge suppression.
Automatically charging when UPS off.
History record of power failure events.
Back up, on-line, battery status, power status display by software.
Schedule shutdown & reboot.
Technical of PWM adjustment and advanced MOSFET power components, ensures stable performance.

2.Technology Specifitions:

w600vaw650vaw800vaw1000va
CAPACITY600VA/360W650VA/390W800VA/480W1000VA/600W
INPUT
Voltage Nominal Voltage 110/120 VAC or 220/230/240 VAC
Acceptable Voltage Range90-145 VAC/150-290 VAC
Frequency Range50 Hz/60HZ
OUTPUT

AC Voltage Regulation

(Batt. Mode)

±10%
Frequency Range(Batt. Mode) 50 Hz or 60 Hz
Transfer Time(Typical)2-6 ms
Waveform(Batt. Mode)Modified Sinewave
BATTERY
Battery Type & Numbers12 V 7 Ah x 112 V 7 Ah x 112 V 9 Ah x 112 V 7 Ah x 2
Back up Time (1PC+15"monitor)15-20 minuters15-25 minuters20-30 minuters20-40minuters
Typical Recharge Time10 hours to 90% after complete discharge
INDICATORS
AC Mode Green LED lighting
Battery ModeGreen LED flashing every 4 seconds
Low Battery at Battery ModeGreen LED flashing every second
FaultRed LED lighting
Battery Fault at AC modesRed LED flashing three times every 2 seconds
Battery Week at AC modesRed LED flashing every 2 seconds for 30 seconds
OverloadRed LED flashing every twice every second
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
Fault Continuously sounding
PHYSICAL
Size,D X W X H (mm) 295*95*140
ENVIRONMENT
Humidity 0 to 90% Relative Humidity(Non-condensing)
Operating Temperature0°Cto 40°C

3.Photos of prducts