Fluke 2625A Data Loggers

Location:
Lake , Mary United
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

Fluke 2625A. Portable Data Acquisition(Data Logger)

Channel Capacity Analog Inputs: 21; Digital I/O & Alarm Outputs: 12 total; Totalizer: 1 Power 90V ac to 264V ac (50 Hz or 60 Hz), or 9V dc to 16V dc; less than 10W. (If both sources are applied simultaneously, the greater of ac or dc is used. At 120V ac the equivalent dc voltage is ~14.5V) Temperature, Humidity (non-condensing) Operating: 0 to 28?C, <=90% RH; 28?C to 40?C, <=75% RH; 40?C to 60?C, <=50% RH; Storage: -40?C to 75?C, 5 to 95% RH Altitude Operating: 3050m (10,000 ft); Storage: 12,200m (40,000 ft) Common Mode and Normal Mode Voltage 300V dc or ac rms (channels 0,1,11); 150V dc or ac rms (all other channels) Isolation Analog input to analog input, and analog input to any digital input: meets IEC 1010 for 300/150 volts reinforced and ANSI/ISA-S82.01-1988 and CSA 231 for 250 volts single insulation Safety Complies with applicable sections of the IEC1010, ANSI/ISA-S82.01-1988, CSA231, UL 1244, CSA 556B, CE. RF Emissions Passes FCC EMI Class A Equipment and VDE 0871B Size 9.3 cm x 21.6 cm x 31.2 cm (3.67" x 8.50" x 12.28") Weight 2.95 kg (6.5 lb) Memory life 10 years typical for real-time clock, set-up configuration and measurement data in 2625A, memory cards typically 5 years for the 256 kB card Interfaces RS-232C connector: nine pin male (DB-9P) Signals TX, RX, DTR, GND Modem Control Full duplex Baud Rates (Set from front panel) 300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4 Echo (Set from front panel) On/Off Flow Control XON/XOFF IEEE-488 (Optional, 2620A Only) Complies with IEEE-488.1 Standard; disables RS-232C Interface while in use Technical Specifications DC Volts Range: 90 mv to 300V Resolution: 1 ?v to 10 mv Accuracy (3-Sigma)1 0.018% AC Volts Range: 90 mV to 300/150V Resolution: 10 ?V to 10 mv Accuracy: (3-Sigma)1 0.13% Resistance Range: 300W to 10 MW Resolution: 10 mW to 1 KW Accuracy: (3-Sigma)1 0.013% Frequency Range: 15 Hz to 1 MHz Resolution: 0.01 Hz to 1 kHz Accuracy: (3-Sigma)1 0.05% RTD (Pt 100) Range: -200 to 600?C Resolution: 0.02?C Accuracy: (3-Sigma)10.05?C J Thermocouples Range: -100 to 760?C Resolution: .01?C Accuracy: (3-Sigma)1 0.39?C K Thermocouples Range: -100 to 1372?C Resolution: .01?C Accuracy: (3-Sigma)1 0.45?C T Thermocouples Range: -150 to 400?C Resolution: .01?C Accuracy: (3-Sigma)1 0.39?C Other Thermocouple types R, S, B, C, E, N 2625A Data Storage Specifications 2625A Data Storage Stores 2047 scans; stored with each scan: time stamp, all defined analog input channels, the status of four alarm outputs and eight digital I/O, and the totalizer count 256K Card Size 4 Channels in Scan 8900 10 Channels in Scan 4800 20 Channels in Scan 2700 1M Card Size 4 Channels in Scan 36,500 10 Channels in Scan 19,800 20 Channels in Scan 11,200 2M Card Size 4 Channels in Scan 74,110 10 Channels in Scan 39,910 20 Channels in Scan 22,550 4M Card Size 4 Channels in Scan 149,000 10 Channels in Scan 80,200 20 Channels in Scan 45,359



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 TEST EQUIPMENT CONNECTION CORP
Phone Number:
  1-407-8041299
Fax Number:
 1-407-804-1277