HXGN 11kv 22kv 33kv 630A gas insulated switchboard

Location:
Shanghai, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

Switchboard:

I.Feautre and benefits:

1.7kv to 36kv are available

2. All insulated and full-sealed

3.Compact and modular design

4, Flexible and smart

5 .Ease of installation and maintainance-free

6 .Ease and safe to operate

7.Competitive price

II.Description

The XGN SF6 ring main unit is made up of modular units containing fi xed, disconnectable orwithdrawable metal-enclosed switchgear, using sulphur hexafl uoride (SF6) or vacuum.

The XGN SF6 ring main unit are used for the MV section in MV/LV transformer substations in publicdistribution systems and MV consumer or distribution substations up to 36 kV.

XGN units are designed for indoor installations. Their compact dimensions are:

a.375 to 1500 mm width
b.1600 to 2250 mm height
c. 840 to 1400 mm depth
this makes for easy installation in small rooms or prefabricated substations.Cables are connected via the front.
All control functions are centralised on a front plate, thus simplifying operation.The units may be equipped with a number of accessories (relays, toroids,instrument transformers, surge arrester, control and monitoring, etc.).

III.Normal operating conditions
Ambient air temperature:
1) less than or equal to 40°C
2) less than or equal to 35°C on average over 24 hours
3) greater or equal to –5°C.
Altitude
1) less than or equal to 1000 m
2) above 1000 m, a derating coeffi cient is applied (please consult us).
Solar radiation
1) no solar radiation infl uence is permitted.
Ambient air pollution
1) no signifi cant pollution by dust, smoke, corrosive and/or flammable gases,
vapours or salt.
Humidity
1) average relative humidity over a 24 hour period, less than or equal to 95%
2) average relative humidity over a 1 month period, less than or equal to 90%
3) average vapor pressure over a 24 hour period, less than or equal to 2.2 kPa
4) average vapor pressure over a 1 month period, less than or equal to 1.8 kPa.
For these conditions, condensation may occasionally occur. Condensation can be
expected where sudden temperature changes occur in periods of high humidity.
To withstand the effects of high humidity and condensation, such as breakdown of
insulation, please pay attention on Civil Engineering recommendations for design
of the building or housing, by suitable ventilation and installation.

IV.Electrical characteristics

Rated votlageUrKV7.21217.52436
Insulation level
Insulation Ud 50/60 Hz, 1 min (kV r ms) 20 28 38 50 70
Isolation Ud 50/60 Hz, 1 min (kV r ms) 23 32 45 60 80
Insulation Up 1.2/50 μs (kV peak) 60 75 95 125 170
Isolation Up 1.2/50 μs (kV peak) 70 85 110 145 195
Breaking capacity
Transformer off load A 16
Cables off load A31.5 50
Rated current A400-630-1250 630-1250
short-time withstand current Ik/tk kA/1s 25 630-1250 1250
20 630-1250
16 630-1250
12.5 400-630-1250 630-1250
Making capacity (50Hz)Ima kA 62.5 630 NA
50 630
40 630
31.25400-630

V.Compartments description

a. Busbar compartment

The three insulated busbars are parallel-mounted. Connection is made to the upper pads of the enclosure using a field distribution with integrated captive screws.

b. Switch compartment

This compartment is separated from the busbar compartment and the connection compartment by the enclosure surrounding the switch, the disconnector and the earthing switch.

c. Connection and switch compartment

d. Operating-mechanism cover

These covers contain the various operating functions for the:switch and earthing switch,disconnector(s),circuit breaker,contactor and the voltage presence indicator.

VI. Cetification

ISO9001:2008

ISO14001:2004

ABB authorized certificate

Schnieder authorized certificate

VII. Ordering Instructions
The purchaser should supply following information for ordering.
a. Scheme of primary circuit
b. Types and specifications of electric components in the switchgear;
c. Material quality and specifications of main bus bar and branch bus bar (according to the manufactory’s standards if not specified);
d. Schematic diagram of small wiring or standard schematic diagram, miniature bus bar array diagram and terminal diagram;
e. Coating color of switchgear;
f. Names and quantity of spare parts
g. Please negotiate with the manufacturer on special requirements.

We're always at your service, any question please feel free to contact us.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Shanghai First Electrical Group Co., Ltd.
Phone Number:
  86-21-64325567
Fax Number:
 86-21-64325822